SC - Set Communications Parameters
Syntax:
sc <speed,length_parity>
[ RETURN ]
The Set Communications Parameters command is used to set the communications link speed,
character length, and parity on the serial port. The default setting is 9600 baud, 8 bit, no parity.
In the syntax above,
sc is the command, speed is the link speed, and Iength_parity are the
character length and parity.
The options for
speed and length_parity are:
speed - 300, 600, 1200, 2400, 4800, 9600, or 19200 baud (trailing zeros maybe omitted,
meaning you may enter sc 24 for 2400 baud)
length_parity
8N - 8 bits no parity
7N - 7 bits no parity
7E - 7 bits even parity
7O - 7 bits odd parity
If either
speed or length_parity are omitted, the current entry is left unchanged.
Sample Command and Response:
> sc 1200,7E
08/14/90 13:48:21 Comms Params Changed to 1200/7E